Product Details:
Minimum Order Quantity | 1 Piece |
Brand | GE Healthcare |
Patient Age Group | Neonatal |
voltage | 100 to 250 V |
frequency | 50 to 60 Hz |
Power Input During Stand By | 115va |
Battery Backup | 45 to 60 Minute |
Features
Important
Product Details:
Type | Anesthesia Ventilators |
Battery Backup Time | no |
Requirement Type | Refurbished |
Storage Relative Humidity | no |
Brand | Maquet |
Max Power Consumption | no |
Patient Age Group | Neonatal, Paediatric, Adult |
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | CAREFUSION |
Model Name/Number | LTV -950 VENTILATORS |
Type | Digital |
Patient Age Group | adult and child |
Operation Mode | Electricity Operated, Battery Operated |
Voltage | 220V AV |
Usage/Application | ICU TRANSPORT |
REFURBISHED
We are actively engaged in offering an extensive range of Nellcor Spo2 Sensor for catering the diversified requirements of our clients.
Product Details:
Type | Critical Care Ventilators |
Brand | GE Healthcare |
Model Name/Number | Versamed iVent 201 |
Patient Age Group | Adult |
Temperature (Device) During Operation | no |
Relative Humidity During Operation | no |
Height Adjustment | no |
With its comprehensive list of standard features, including the latest modes of ventilation, the iVent201 is appropriate for all levels of patient acuity, from pediatric through adult, and in all care settings, from the patient’s bedside to transport to another point of care.
With its highly featured transport capability and rugged construction, the iVent201 takes ICU ventilation outside of the confines of the hospital. Optimized NIV and the Adaptive Bipap help caregivers maximize patient comfort and synchrony.
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name | Oxylog |
Requirement Type | New |
Battery Backup Time | upto 6 hours |
Tidal Volume | 0.1 to 1.5 L infinitely adjustable |
Brand | Drager |
Mains power connection | 11 to 30 V direct voltage when operated off vehicle electrical system with DC/DC converter or 230 VA |
Model Name/Number | Oxylog 2000 |
Ventilation Modes | IPPV, SIPPV, SIMV, CPAP |
Mounting Type | Portable |
The Dräger Oxylog 2000 is a transport ventilator designed to provide support to a patient’s failing respiratory system. Because a ventilator provides vital oxygen to the lungs of a patient who is experiencing difficulty breathing on their own, these devices must be designed with several control mechanisms to provide the correct pressures and oxygen levels suitable for a given patient. The Oxylog 2000 features a compact and rugged design for portability and ease of use, as the ventilator is primarily used in emergency situations or during patient transport. It offers several volume-controlled modes such as IPPV/CMV, SIPPV / A/C, CPAP, and SIMV. It also supports both invasive and non-invasive ventilation.
The Oxylog 2000 uses standardized disposable tubes, which are compatible with the Oxylog 3000. An LCD screen in conjunction with an analog pressure gauge supply the operator with all the volume, pressure, and frequency information they need.
Key features of the Drager Oxylog 2000:
Technical Specifications